Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Biosci. j. (Online) ; 34(3): 587-594, mai/jun. 2018. tab, graf
Article in English | LILACS | ID: biblio-966904

ABSTRACT

This study evaluated the adjustment of four kinetic models and their respective parameters on data of dairy wastewater treatment by the physico-chemical process of flotation and ozonation. The experiment was implemented during the year 2014, with all the tests in triplicate. The treatments were carried out at different pH levels (3.6, 7.0 and 10.4), and flotation/ozonation was catalyzed by manganese (Mn2+) in neutral level (pH 7.0). Best removal efficiencies for chemical oxygen demand (COD) were obtained in acidic medium, with removals greater than 75% after 20 min of treatment. There was no significant difference with regards to addition of Mn2+ on COD removal by the physicochemical process. The kinetic models that best fit to the experimental data, for all treatments, were the asymptotic (residual) model and that of Chan and Chu. Treatment in acidic medium showed the highest values of the kinetic parameters for the adjusted model, obtaining a k coefficient equal to 0.2394 min-1 for the asymptotic model and kinetic coefficient 1/ of 0.4816 min-1 for the Chan and Chu model, both presenting a determination coefficient greater than 99%.


Neste estudo, avaliou-se o ajuste de quatro modelos cinéticos (modelo de escoamento pistonado, mistura completa, assintótico ou residual e de Chan e Chu e seus respectivos parâmetros, na degradação da matéria orgânica presente no efluente de laticínios pelo processo físico-químico de flotação e ozonização. O experimento foi implementado durante o ano de 2014, com todos os testes em triplicata, os s tratamentos foram realizados sob diferentes pHs (3,6; 7,0 e 10,4), além da flotação/ozonização catalisada pelo manganês (Mn2+) em meio neutro. Observando que em meio ácido ocorreram as melhores eficiências de remoção da demanda química de oxigênio (DQO), tendo sido obtida uma remoção superior a 75% em 20 min de tratamento. Não houve diferença significativa em relação à adição de Mn2+ ao processo físico-químico. Os modelos que mais se ajustaram aos dados experimentais, para todos os tratamentos realizados, foram o modelo assintótico e o de Chan e Chu. O tratamento em meio ácido foi o que apresentou os maiores valores dos parâmetros cinéticos para os modelos ajustados, obtendo-se para o modelo assintótico, coeficiente k igual a 0,2394 min-1, e para o modelo de Chan e Chu, coeficiente cinético 1/ de 0,4816 min-1, apresentando para ambos os modelos um coeficiente de determinação superior a 99%.


Subject(s)
Kinetics , Flotation , Ozonation , Organic Matter , Wastewater , Chemical Waste Degradation , Dairying , Biological Oxygen Demand Analysis , Manganese
2.
São Paulo; s.n; 2009. 149 p. ilus, tab, graf.
Thesis in Portuguese | LILACS | ID: lil-533694

ABSTRACT

Introdução Análise da qualidade da água do reservatório Billings, situado na região Metropolitana de São Paulo, em decorrência do bombeamento de água proveniente de duas estações de Flotação experimentais, situadas no rio Pinheiros. Objetivo Analisar parâmetros de qualidade da água revertida para o reservatório Billings, sob o aspecto de poluição e toxicidade, objetivando a utilização deste reservatório para reúso recreacional e também para geração de energia na Usina Henry Borden em Cubatão. Metodologia Para a pesquisa quantitativa foram utilizados dados secundários, coletados ao longo de 22 de agosto de 2007 a 31 de maio de 2008, sendo este o período de funcionamento do sistema de flotação, nos pontos de amostragem convencionais e também nos pontos com monitoramento contínuo, em locais previamente estabelecidos. Resultados A análise indicou que o primeiro ponto de monitoramento dentro da represa sofre os efeitos diretos do bombeamento, o que não se constata nos pontos mais distantes do corpo central do reservatório. Apontou também a presença de alguns contaminantes importantes como chumbo e clorofórmio na água, em quantidade acima do permitido na legislação. Conclusão - A utilização do reservatório para reúso recreacional com contato primário está contra indicada e o bombeamento das águas para geração de energia pode ser mantido, uma vez que a qualidade de água para esta aplicação deverá ter baixa quantidade de sólidos, que são removidos pela flotação. Recomendações - Realização de estudos que contemplem a análise conjunta da influência dos benefícios oriundos do Programa de Despoluição do Tietê, em implantação pela Companhia de Saneamento Básico de São Paulo, e também do sistema de tratamento por flotação. Ajustes operacionais e adequações no sistema de flotação. Mapeamento e identificação de fontes de lançamento de esgotos diretamente no corpo da represa, e eliminação destas emissões clandestinas. Controle rigoroso da ocupação de áreas no entorno da Billi...


Subject(s)
Flotation , Water Reservoirs , Water Quality , Water Recycling
3.
Tropical Biomedicine ; : 154-9, 2008.
Article in Malayalam | WPRIM | ID: wpr-629790

ABSTRACT

A study was carried out in order to find out the status of Giardia spp. and Sarcocystis spp. in pet dogs and stray cats of Shiraz, Fars Province of Iran. Faecal samples of 147 pet dogs and 112 stray cats of different age groups, breeds, and sexes were tested. The stools were examined with the following techniques: direct faecal smears using normal saline, zinc sulfate flotation and formalin-ether concentration technique. Out of a total of 147 pet dogs examined, only one case (0.68%) of Giardia spp. was observed. A total of 3 (2.04%) pet dogs were found positive for Sarcocystis spp. Specimens from stray cats were also examined, however no Giardia spp. trophozoite or cyst was observed in these specimens.


Subject(s)
Giardia , Sarcocystis , Iran , Flotation
4.
Eng. sanit. ambient ; 12(3): 273-283, jul.-set. 2007. ilus, tab
Article in Portuguese | LILACS | ID: lil-466563

ABSTRACT

O artigo apresenta um método proposto para determinação de tamanho de microbolhas de ar (DTMB) em sistemas de tratamento de água por flotação por ar dissolvido (FAD), utilizando a análise de imagem digital. Adicionalmente, é apresentado um estudo de caso com emprego de unidade em escala piloto. A aquisição das imagens foi realizada com uma câmera digital de 5.1MPixel, acoplada a conjunto de lentes. As imagens de microbolhas foram adquiridas em sistema com escoamento contínuo para eliminar as interferências causadas pela captura de amostras. O tratamento e obtenção das feições foram realizadas com o programa (freeware) "ImageTool". Os resultados apresentaram coerência com os valores reportados na literatura utilizando métodos tradicionais. O sistema mostrou-se eficaz e o método desenvolvido pode constituir ferramenta útil para estudos em outras subáreas de conhecimento.


An image analysis method proposed for assessing bubble size distribution applied to dissolved air flotation (DAF) systems for drinking water treatment is presented. Further, a pilot plant investigation is presented. A digital camera together with a group of lens was used. In order to eliminate samples interferences the images were captured in a continuous flow system working in steady state. The freeware ImageTool was applied for treating and obtaining size distribution. Results were presented in good relationship with traditional methods. The role image system showed to be efficient for image capturing and the proposed method may be an useful tool to other researches areas.


Subject(s)
Case Reports , Flotation , Image Processing, Computer-Assisted , Particulate Matter , Water Purification
5.
Eng. sanit. ambient ; 11(3): 260-268, jul.-set. 2006. graf, tab
Article in Portuguese | LILACS | ID: lil-445776

ABSTRACT

O reagente de Fenton foi empregado como agente coagulante no tratamento de água com cor verdadeira elevada (100 ± 5 uH) causada pela introdução de substâncias húmicas extraídas de turfa, empregando-se a flotação por ar dissolvido. Otimizou-se o par de valores dosagem de coagulante x pH de coagulação para posterior construção dos diagramas de coagulação, obtendo-se eficiências de remoção de cor aparente pouco superiores a 60 por cento. Procurou-se simular um tratamento em ciclo completo, realizando-se ensaio de filtração em areia após flotação, obtendo-se efluente de excelente qualidade, apresentando cor aparente, turbidez e absorvância a 253,7 nm remanescentes menores ou iguais a 2 uH, 0,40 uT e 0,009 cm-1, respectivamente, e ferro total residual < 0,005 mg/L e COD < 0,001 mg/L.


Fenton's reagent was used as coagulant agent to treat water with high true color (100 ± 5 HU) caused by the introduction of humic substances extracted from peat, using dissolved air flotation. The pair value of coagulant dosage x coagulation pH was optimized to posterior construction of coagulation diagrams, reaching apparent color removal efficiency slightly superior to 60 percent. It was tried to simulate a treatment with complete cycle, carrying out an experiment with sand filtration after flotation, obtaining an effluent with excellent quality, presenting remnant apparent color, turbidity and absorbance of 253.7 nm less or equal to 2 HU, 0.40 TU and 0.009 cm-1, respectively, and residual total iron< 0.005 mg/L and DOC < 0.001 mg/L.


Subject(s)
Coagulants (Water Treatment) , Drinking Water , Flotation , Humic Substances , Oxidants , Water Quality , Water Purification
SELECTION OF CITATIONS
SEARCH DETAIL